BIOMEDICAL PROJECTS-Digital Pulmonary Function Test – Spirometry
ABSTRACT:-
Pulmonary function test is
helpful in diagnosis lung diseases. It helps the doctor to detect the range of
respiratory diseases. This test can be helpful to cure respiratory diseases if
detected early. The simplest test is spirometry, which measures how fast the
lungs can breath in and out, and also the volume of air lung can exhaled in the
first and second of test. A peak flow meter can determine how much a patient’s
airways have narrowed.
Our
aim is to make a microcontroller based spirometer which displays the output in
form of signals.
Spirometry (meaning the measuring of breath) is the most common of the
Pulmonary Function Tests (PFTs), measuring lung function, specifically the
measurement of the amount (volume) and/or speed (flow) of air that can be
inhaled and exhaled. Spirometry is an important tool used for generating
pneumotachograph to assessing conditions such as asthma, pulmonary fibrosis,
and COPD.
The basic FVC test varies slightly depending on the equipment used.
Generally, the patient is asked to take the deepest breath they can, and
then exhale into the sensor as hard as possible, for as long as possible. It is
sometimes directly followed by a rapid inhalation (inspiration), in particular
when assessing possible upper airway obstruction. Sometimes, the test will be
preceded by a period of quiet breathing in and out from the sensor (tidal
volume), or the rapid breath in (forced inspiratory part) will come before the
forced exhalation.
During the test, soft nose clips may be used to prevent air escaping
through the nose. Filter mouthpieces may be used to prevent the spread of
microorganisms, particularly for inspiratory maneuvers.
SENSOR:
We have used a
Turbine Flow sensor to measure the Tidal Volume. If air is blown into the
sensor, the fan inside the sensor rotates and a proximity sensor kept nearby
will generate an series of pulse signals, which is then amplified and given as
a pulse input to the PIC Microcontroller for Display.
For
Eg: if the 7ml of gas goes to the rotor and rotor will give 1 pulse.so we have
taken 1pulse=7ml.and as per the count we make program for microcontroller to
count pulses.
CONTACT:
MEGATECH
NO7,KANNAN AVENUE 1ST CROSS STREET,
MUDICHUR ROAD,OLD PERUNGALATHUR,
TAMBARAM WEST-CHENNAI 63
(NEAR HERO SHOWROOM,ANNAI ARUL HOSPITAL)
TEL:044 22761990
WHATSAPP:98402 34766
MOBILE:81444 34766,9659246311
WEBSITE: http://megatechallprojects.blogspot.in/
EMAIL: megatechallprojects@gmail.com
MEGATECH
NO7,KANNAN AVENUE 1ST CROSS STREET,
MUDICHUR ROAD,OLD PERUNGALATHUR,
TAMBARAM WEST-CHENNAI 63
(NEAR HERO SHOWROOM,ANNAI ARUL HOSPITAL)
TEL:044 22761990
WHATSAPP:98402 34766
MOBILE:81444 34766,9659246311
WEBSITE: http://megatechallprojects.blogspot.in/
EMAIL: megatechallprojects@gmail.com
No comments:
Post a Comment